HXK95VSD - Refrigerant Type: R600a
- Cooling Capacity: 41.3-115.4W - COP: 1.73-2.05 W/W​
|
Application | |
Type | Hermetic Reciprocating Compressor |
Refrigerant | R600a |
Nominal Voltage and Frequency | 220-240//50/60[V//Hz] |
Application Type | Low back pressure |
Max Condensing temperature | 60 [°C] |
Evaporating temperature range | (-10 [°C] ─ -35[°C] ) |
Max Ambient temperature | 43 [°C] |
Maximum winding temperature | 130 [°C] |
Expansion device | Capillary Tube |
Compressor cooling | Static |
Performance Data | |
Test standard | ASHRAE |
Cooling Capacity (W) [with capacitor] | 60-208 |
Power consumption (W) [with capacitor] | 41.3-115.4 |
COP (W/W) [with capacitor] | 1.80-1.97 |
Rated Current (A) | 0.25-0.84 |
Mechanical Data | |
Displacement volume | 9.6 [cmá¶¾] |
Net weight | 6.2 [Kg] |
Oil type | Mineral |
Oil charge | 165 [ml] |
Oil viscosity | 7 [cst] |
Suction muffler | Semi Direct |
Length, L | 194.2 [mm] |
Width, W | 151.5 [mm] |
Height, H | 139.5 [mm] |
Metrology Lab:
 Height gauge: Accuracy- (1.1+0.6L/600) µm.
 Vision measuring system: Accuracy- (1.9+L/100) µm,1D and (2.9+L/100) µm.
 CNC CMM: Accuracy- (1.8+L/300) µm.
 Surface roughness and Contour machine: Accuracy- Roughness 0.25 µm and Contour 0.50 µm.
 Roundness machine: Accuracy 0.25 µm.
Materials Testing and Analysis Lab:
 Wire Testing Facilities
 Hardness Testing Facilities
 Macro and Micro Analysis facilities
 Spring Testing Facilities
 Gasket Thickness Measurement Machine
And also contains versatile testing machines for checking different raw materials characteristics
 Overload Test Machine
 Quick Test Machine
 Locked Rotor Test Machine
 OLP Test Machine
Noise Testing Chamber:
 Testing facilities for the measurement of Noise, Vibration and Gas pulsation
 Background Noise Level < 10dB
 Standard : ISO 3744
Life Testing Machine:
 258 benches are dedicated to perform Wear, High Temperature and ON/OFF Test
 Standard: CECOMAF GT4